NanaWall - Large Exterior Openings
Skip Navigation LinksHome > Products > Selection > Performance Comparison
Weather Resistance Structural Integrity
Water
Penetration (1)
ASTM E-547-86
No Penetration At:
Air
Infiltration (2)
ASTM E-283
Thermal
Integrity (3)
NFRC U-Factor
Structural Load Deflection (5)
ASTM E-330-90
Pass At: Design Pressure
Forced Entry
Resistance (6)
AAMA 1303.5
CAWM 300-96
6.24 psf (50 mph) Range Positive Negative
Glazed Folding System
SL60
Inward 12 psf (68 mph) 0.18 0.51 - 0.24 NFRC 34psf 34psf Yes
Outward 9 psf (60 mph) 0.11 0.51 - 0.25 NFRC 34psf 34psf Yes
SL45
Inward 1.56 psf (25 mph) N/A 1.16 - 0.57 28psf 28psf Yes
Outward 1.56 psf (25 mph) N/A 1.16 - 0.57 28psf 28psf Yes
SL70
Inward 12 psf (68 mph) 0.18 0.52 - 0.21 NFRC 70psf 100psf Yes
Outward 12 psf (68 mph) 0.12 0.52 - 0.21 NFRC 100psf 70psf Yes
SL72 HURRICANE
Inward 8.25 psf (56 mph) 0.27 - 0.32 Data Pending 55psf 90psf Yes
Outward 8.25 psf (56 mph) 0.20 - 0.37 Data Pending 55psf 55psf Yes
SL35
Inward 3.00 psf (34 mph) 0.32 1.16 - 0.55 29psf 29psf Yes
Outward 5.25 psf (45 mph) 0.24 1.16 - 0.55 29psf 29psf Yes
WA67
Inward 12 psf (68 mph) 0.23 0.50 - 0.25 NFRC 56psf 74psf Yes
Outward 12 psf (68 mph) 0.28 0.49 - 0.25 NFRC 74psf 56psf Yes
WD66
Inward 12 psf (68 mph) 0.03 0.47 -0.26 NFRC 34psf 46psf Yes
Outward 12 psf (68 mph) 0.18 0.47 -0.26 NFRC 46psf 34psf Yes
WD65
Inward Data Pending 0.38 0.86 - 0.47 40psf 40psf Yes
Outward Data Pending 0.38 0.86 - 0.47 40psf 40psf Yes
Single Track Sliding System
HSW65 (7)
Stacking 7.5 psf (54 mph) 0.46 0.54 - 0.38 49psf 49psf Yes
VSW65 (7)
Stacking 7.5 psf (54 mph) 0.46 0.54 - 0.38 49psf 49psf Yes
HSW50
Stacking 3.75 psf (39 mph) 0.44 0.56 - 0.34 NFRC 50psf 50psf Yes
VSW35
Stacking Data Pending Data Pending 1.16 - 0.55 Data Pending Data Pending Data Pending
SL25
Stacking N/A N/A N/A 40psf 45psf N/A
(1) Water Penetration (ASTM E-547-86). Ratings shown are for units with raised sills. Ratings for units with flush/saddle sills are dependent on drain connections by others.
(2) Air Infiltration (ASTM E-283). Cubic feet per minute per linear feet of crack. Ratings shown are for units with raised sills. Ratings on units with flush/saddle sills may be less.
Data also available for lower wind speed.
(3) Computer simulated in accordance with NFRC 100. Ranges shown are with insulated glass types.
(4) Rated, certified and labeled in accordance with NFRC 100. Ranges shown are with insulated glass types.
(5) Structural Load Deflection (ASTM E-330-90). Ratings shown are for units with reinforced locking points. For comparison purposes, ratings are shown from comparative analysis for 3' x 8' panels.
Higher loading is possible with smaller panel sizes.
(6) Forced Entry Resistance — Compliance with AAMA 1303.5 and CAWM 300-96 requirements.
(7) For testing purposes, the VSW65 and the HSW 65 are considered the same system
Note: Before final selection, please see testing results for each system with consideration for testing conditions, panel configurations and installation details.
NFRCNFRC Certified